Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
J Clin Med ; 13(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38398292

RESUMO

(1) Background: Endovascular abdominal aneurysm repair (EVAR) is associated with a reduction in early morbidity and mortality compared with open repair. Procedures performed under hypnosis might represent an alternative to further reduce the risks related to general anesthesia (GA). This study aimed to assess the feasibility and safety of hypnosis and local anesthesia during EVAR. (2) Methods: All consecutive patients who underwent EVAR or fenestrated/branched EVAR (f/bEVAR) under hypnosis and local anesthesia (n = 28) between 2017 and 2019 were retrospectively studied and matched to control patients who underwent the same interventions under GA. (3) Results: There was neither a significant difference in the length of ICU stay (p = 0.06), nor in the occurrence of endoleaks, reintervention, and 30-day mortality rate (p = 1.00, 0.73, and 0.24, respectively). The hypnosis group had lower use of norepinephrine (maximum dose 0.04 ± 0.1 vs. 1.2 ± 4.0 mg·h-1, p < 0.001), shorter procedure duration (181.2 ± 71.4 vs. 214.3 ± 79.6 h, p = 0.04), and shorter length of stay (5.4 ± 3.2 vs. 8.4 ± 5.9 days, p = 0.002). (4) Conclusions: In this pioneering study, hypnosis during EVAR appears feasible and safe. It is associated with lower intraoperative use of norepinephrine, as well as procedure duration and length of in-hospital stay.

2.
Data Brief ; 52: 110004, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38235183

RESUMO

Adjuvant radiotherapy for breast cancer may involve some incidental exposure of the ipsilateral internal mammary artery to ionizing radiation. However, the relevant evidence is limited and inconsistent. The dataset presented in this article contains the information used to assess the effects of accidental radiation exposure on the internal mammary artery in patients with unilateral total mastectomy followed radiotherapy for breast cancer. The study population consists of two groups: the irradiated group and the control group. The left and right internal mammary arteries were assessed through the second intercostal spaces using a computed sonography system (Vivid S6; GE, Tirat Carmel, Israel) equipped with a 5.5 - 11 MHz transducer. The recorded parameters were the diameter, time-averaged maximum velocity, and blood flow of the internal mammary artery. The dataset contains two files of data: a raw and an analyzed data. The raw data file contains the individual information of each participant, including demographic characteristics and the parameters of the internal mammary artery duplex ultrasound imaging. The analyzed data file was made up of R Markdown, a markup language of R. The results of data analysis were presented in the related research article which has been accepted for publication in the Annals of Vascular Surgery. The dataset presented in this article may be reused for further studies in which the internal mammary artery is considered as potential donor or recipient vessels for a vascular bypass or free flap anastomosis.

3.
Ann Vasc Surg ; 100: 15-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38110082

RESUMO

BACKGROUND: The effects of incidental radiation exposure on internal mammary arteries remain unclear. The present study was designed to test the hypothesis by comparing diameter and blood flow of the irradiated and nonirradiated internal mammary arteries, using Duplex ultrasound imaging. METHODS: The study was designed as a single-center, transversal, comparative study. The main outcomes were diameter and volumetric blood flow of the internal mammary arteries. The Wilcoxon rank-sum test was used to assess the differences between the irradiated and nonirradiated internal mammary arteries with regard to the diameter and volumetric blood flow. RESULTS: The diameter (median [interquartile range]) of the irradiated internal mammary arteries (0.170 mm [0.160, 0.180]) was smaller than that of the contralateral nonirradiated ones (0.180 mm [0.170, 0.200], P < 0.0001) and that of the internal mammary arteries in the control group (0.180 mm [0.170, 0.190], P < 0.0001). Similarly, blood flow (median [interquartile range]) of the irradiated internal mammary arteries (52.4 ml/min [37.78, 65.57]) was smaller than that of the contralateral nonirradiated ones (62.7 ml/min [46.87, 84.17], P < 0.0001), as well as of the left (56.7 ml/min [46.88, 72.58], P = 0.02) and the right internal mammary arteries in the control group (61.0 ml/min [47.47, 74.52], P = 0 0.0009). CONCLUSIONS: The data indicate that the irradiated internal mammary arteries in patients with a history of total mastectomy followed by radiotherapy for breast cancer had significantly smaller diameter and blood flow compared to the nonirradiated internal mammary arteries.


Assuntos
Neoplasias da Mama , Artéria Torácica Interna , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Artéria Torácica Interna/diagnóstico por imagem , Mastectomia Simples , Mastectomia , Resultado do Tratamento
5.
Eur J Vasc Endovasc Surg ; 66(6): 821-829, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37567339

RESUMO

OBJECTIVE: A proximal scallop design allows aortic arch repair without complex endovascular manipulation in the aortic arch. The aim was to assess the safety and efficacy at one year of the Relay proximal scallop stent graft. METHODS: A prospective multicentre study evaluated consecutive patients treated with the Relay proximal scallop stent graft in 10 French aortic centres. All consecutive patients eligible for elective thoracic endovascular repair with proximal scallop in the 10 participating centres between January 2015 and July 2018 were included. Primary endpoints were 30 day mortality, stroke, and spinal cord ischaemia (SCI) rates. Outcomes including safety and efficacy, technical and clinical success, all cause death, neurological events, vessel patency, and device specific complications were analysed. Survival and survival without severe complications were estimated using Kaplan-Meier estimates. RESULTS: Ten aortic centres treated 40 patients for thoracic aortic aneurysm (45%), penetrating atherosclerotic aneurysm (30%), and dissection (25%). Half of the procedures (50%) targeted zone 0 of the aortic arch (zone 0 in 17.5% and zones 0/1 in 32.5%), 37.5% targeted zone 2 (35% zone 2 alone; 2.5% zones 1/2), and 15% targeted zone 1 (12.5% zone 1 alone). Median follow up was one year. Thirty day mortality, stroke, and SCI rates were 10%, 5%, and 0% respectively. Primary technical success was 95%. Type Ia, Ib, and III endoleaks rates were 5.4%, 0%, and 0% respectively at one month. The overall mortality rate at one year was 17.5%. Aneurysm expansion was > 5 mm in one case at one year associated with type Ia endoleak (3%). There was no supra-aortic trunk thrombosis, one (2%) graft kink, and no migration. CONCLUSION: One year outcomes showed that the Relay proximal scallop stent graft is an acceptable answer to thoracic aortic disease to deal with short proximal landing zones.


Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Doenças da Aorta , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Stents/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/complicações , Endoleak/etiologia , Endoleak/cirurgia , Acidente Vascular Cerebral/cirurgia , Estudos Retrospectivos
6.
Ann Vasc Surg ; 95: 50-61, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37270093

RESUMO

BACKGROUND: The purpose of this study was to compare postoperative morbi-mortality and medium-term follow-up of fenestrated stent grafting and open repair (OR) for patients with juxtarenal aortic aneurysms (JRAAs). METHODS: All consecutive patients who underwent custom-made fenestrated endovascular aortic repair (FEVAR) or OR for complex abdominal aortic aneurysm between 2005 and 2017 in 2 tertiary centers were scrutinized. Patients with JRAA constituted the study group. Suprarenal and thoracoabdominal aortic aneurysms were excluded. The groups were made comparable through the use of a propensity score matching. RESULTS: 277 patients with JRAAs were included, 102 (36.8%) in the FEVAR group and 175 (63.2%) in the OR group, respectively. After propensity score matching, 54 FEVAR patients (52.9%) and 103 OR patients (58.9%) were included for analysis. In-hospital mortality rates were 1.9% (n = 1) in the FEVAR group versus 6.9% (n = 7) in the OR group (P = 0.483). Postoperative complications were less common in the FEVAR group (14.8% vs. 30.7%; P = 0.033). Mean follow-up was 42.1 months in the FEVAR group and 40 months in the OR group. Overall mortality rates at 12 and 36 months were 11.5% and 24.5% in the FEVAR group versus 9.1 % (P = 0.691) and 11.6% (P = 0.067) in the OR group. Late reinterventions were more frequent in the FEVAR group (11.3% vs. 2.9%; P = 0.047). However, freedom from reintervention rates were not significantly different at 12 months (FEVAR: 86% vs. OR: 90%; P = 0.560) and 36 months (FEVAR: 86% vs. OR: 88.4%, P = 0.690). In the FEVAR group, persistent endoleak during follow-up was identified in 11.3% of cases. CONCLUSIONS: In the present study, there was no statistical difference in terms of mortality in-hospital at 12 or 36 months between FEVAR and OR groups for JRAA. FEVAR for JRAA was associated with a significant reduction of overall postoperative major complications compared with OR. There were significantly more late reinterventions in the FEVAR group.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Implante de Prótese Vascular/efeitos adversos , Pontuação de Propensão , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia
7.
Ann Vasc Surg ; 93: 38-47, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36460175

RESUMO

BACKGROUND: To assess midterm results of physician-modified stent grafts (PMSG) for the treatment of emergent complex abdominal and thoracoabdominal aortic aneurysms (TAAA) in high-risk patients. METHODS: All consecutive patients with emergent complex abdominal or TAAA undergoing PMSG technique between January 2012 and July 2019 were retrospectively included. Indications for PMSG were symptomatic aneurysms and rapidly growing aneurysms >70 mm. Ruptured aneurysms were excluded. RESULTS: Thirty-three patients (mean age: 74 +/- 11 years) were included. The mean aneurysm diameter was 76 +- 20 mm. Patients presented with TAAA (n = 20, 61%), complex abdominal aortic aneurysms (CAAA, n = 9, 27%), type I endoleak after previous endovascular aneurysm repair (n = 3, 9%) and intramural aortic hematoma (n = 1, 3%). Chimney technique was performed in addition to PMSG in seven cases (21%). Intraoperative adverse events were recorded in seven cases (35%) in the TAAA group and one case (11%) in the CAAA group. In-hospital mortality rate was 15% (n = 3) in the TAAA group and 11% (n = 1) in the CAAA group. Moderate to severe complications were recorded in 45% of cases (n = 15). Spinal cord ischemia occurred in two cases (6%, one case without residual deficit and one with minor motor deficit). One (3%) patient required transient hemodialysis. One patient presented with early aortic rupture and required an open conversion. The mean follow-up duration was 31 months (1-79). Overall survival estimates were 81.4% (95% confidence interval [CI]: 63.1.-91.2) at 1 year and 71.6% (95% CI: 52.6-84.1) at 2 years. Freedom from reintervention rates at 1 and 2 years were 61.2% (95% CI: 41.7-75.9) and 57.4% (95% CI: 37.9-72.8). Target vessel primary patency rates at 1 and 2 years were 99.2% (95% CI: 94.2-99.9) and 97.7% (95% CI: 90.7-99.4). CONCLUSIONS: PMSG for high-risk patients with complex aneurysms provided acceptable technical success and excellent target vessel patency rates but were associated with a 12% in-hospital mortality rate. Reinterventions were frequent. This technique should be limited to selected high-risk patients for whom the risk of rupture in the short-term is deemed too high to wait for graft manufacturing of custom-made device.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Stents , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Desenho de Prótese , Fatores de Tempo
9.
Ann Vasc Surg ; 86: 35-42, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35780947

RESUMO

BACKGROUND: COVID-19 infection is associated not only with venous thromboses but also with arterial thromboses (COV-ATs) in relation with an endothelial dysfunction, a coagulopathy and rhythm disorders. The incidence, the topography, and the prognosis of COV-ATs remain poorly known. The objective of this study was to report the overall experience of the Greater Paris University Hospitals (Assistance Publique - Hopitaux de Paris, AP-HP) during the first pandemic wave of COVID-19 infection. METHODS: After approval by the ethics committee, a study using the AP-HP clinical data warehouse was carried out between March and May 2020. Overall, 124,609 patients had a polymerase chain reaction for COVID-19 in our hospitals, of which 25,345 were positive. From 20,710 exploitable stays, patients tested positive for COVID who presented an episode of acute COV-AT (except coronary and intracranial arteries) were selected on the basis of the French medical classification for clinical procedures codes. The data are presented as absolute values with percentages and/or means with standard deviation. RESULTS: Over the studied period, 60 patients (aged 71±14 years, 42 men) presented a COV-AT at the time of their hospitalization, an incidence of 0.2%. The arterial complication occurred 3±7 days after the COVID infection and was inaugural in 30% of the cases (n = 18). The sites of COV-AT were the lower extremities (n = 35%, 58%), the abdominal aorta (n = 10%, 17%), the thoracic aorta (n = 7%, 12%), the upper limbs (n = 7%, 12%), the cerebral arteries (n = 7%, 12%), the digestive arteries (n = 6%, 10%), the renal arteries (n = 2%, 3%), and the ophthalmic artery (n = 1%, 2%). Multiple COV-ATs were observed in 13 patients (22%). At the time of diagnosis, 20 (33%) patients were in intensive care, including six (10%) patients who were intubated. On computed tomography angiography, COVID lesions were classified as moderate and severe in 25 (42%) and 21 (35%) cases, respectively. Revascularization was attempted in 27 patients (45%), by open surgery in 16 cases, using endovascular techniques in 8 cases and with a hybrid approach in three cases. Six patients (22%) required reinterventions. The duration of hospitalization was 12±9 days. Early mortality (in-hospital or at 30 days) was 30% (n = 18). Nine (15%) patients presented severe nonlethal ischemic complications. CONCLUSIONS: Arterial involvement is rare during COVID-19 infection. The aorta and the arteries of the limbs are the privileged sites. The morbi-mortality of these patients is high. Future studies will have to determine if the systematization of anticoagulation therapy decreases the incidence and the severity of the condition.


Assuntos
COVID-19 , Trombose , Masculino , Humanos , SARS-CoV-2 , Resultado do Tratamento , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/terapia , Artérias
10.
Eur J Vasc Endovasc Surg ; 63(3): 475-483, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34872811

RESUMO

OBJECTIVE: Mycotic/infective native aortic aneurysms (INAA) are managed heterogeneously. In the context of disparate literature, this study aimed to assess the outcomes of INAA surgical management and provide comprehensive data in alignment with recent suggestions for reporting standards. METHODS: A retrospective review of patients presenting with INAA from September 2002 to March 2020 at two institutions was conducted. In hospital mortality, 90 day mortality, overall mortality, and infection related complications (IRCs) were the study endpoints. Overall survival and IRC free survival were estimated, and predictors of mortality tested using uni- and multivariable analyses. RESULTS: Seventy patients (60 men [86%], median age 68 years [range 59 - 76 years]) were included. Twenty (29%) were ruptured at presentation. INAA location was thoracic in 11 (16%) cases, thoraco-abdominal in seven (10%), and abdominal in 50 (71%). Half of the abdominal INAAs were suprarenal. Two INAAs were concomitantly abdominal and thoracic. Pathogens were identified in 83%. The bacterial spectrum was scattered, with rare Salmonella species (n = 6; 9%). Open surgical repair was performed in 66 (94%) patients, including five conversions of initially attempted endovascular grafts (EVAR), three hybrid procedures, and one palliative EVAR. Vascular substitutes were cryopreserved arterial allografts (n = 67; 96%), prosthesis (n = 2), or femoral veins (n = 1). Kaplan-Meier estimates of overall survival at 30 and 90 days were 87% (95% confidence interval [CI] 76.6 - 93.0) and 71.7% (95% CI 59.2 - 80.9), respectively. The overall in hospital mortality rate was 27.9% (95% CI 1.8 - 66.5). IRCs occurred in seven (10%) patients. The median follow up period was 26.5 months (range 13.0-66.0 months). Chronic kidney disease (CKD) was independently related to in hospital mortality (odds ratio [OR] 20.7, 95% CI 1.8 - 232.7). American Society of Anesthesiologists score of 3 (OR 6.0, 95% CI 1.1 - 33.9), 4 (OR 14.9, 95% CI 1.7 - 129.3), and CKD (OR 32.0, 95% CI 1.2 - 821.5) were related to 90 day mortality. CONCLUSION: Surgical INAA management has significant mortality and a low re-infection rate. EVAR necessitated secondary open repair, but its limited use in this report did not allow conclusions to be drawn.


Assuntos
Aneurisma Infectado , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aloenxertos/cirurgia , Aneurisma Infectado/microbiologia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
11.
Eur J Vasc Endovasc Surg ; 62(2): 204-213, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33994306

RESUMO

OBJECTIVE: The aim was to describe initial outcomes of physician modified stent grafts using antegrade laser fenestrations and image fusion guidance (LEVAR) and company manufactured custom made (CM) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs), thoraco-abdominal aortic aneurysms (TAAAs) and type I endoleaks (T1ELs). METHODS: This was a retrospective single centre study. All LEVAR and Zenith (Cook) CM stent graft procedures between 1 January 2012 and 31 December 2018 were reviewed. Endpoints included intra-operative adverse events (IOAEs), in hospital mortality, re-interventions, target vessel patency, and 12 month outcomes (overall survival, freedom from re-intervention, target vessel patency). Outcomes at 12 months were estimated using the Kaplan-Meier method. RESULTS: A hundred patients were identified and included in the study. All patients were deemed unfit for open repair. The cohort included 22 LEVAR and 78 CM stent grafts. LEVAR cases included painful aneurysms (n = 5), > 65 mm aneurysms (n = 10), anatomical constrains and/or presence of previous renal stents (n = 7) or cases declined by the manufacturer planning centre (n = 2). IOAEs were recorded in 41% of cases (n = 9) in the LEVAR group vs. 10% (n = 8, p = .002) in the CM group. The in hospital mortality rate in the LEVAR group was 9% (n = 2) vs. 4% (n = 3, p = .30) in the CM group. The median follow up duration was 22 months (7 - 38) in the LEVAR group and 28 months (11 - 78) in the CM group. The estimate of overall survival at one year was 91% in both groups. The freedom from re-intervention rate at one year was 58% in the LEVAR group vs. 87% in the CM group. The target vessel patency rates at one year were 95% in both groups. CONCLUSION: In high risk patients deemed unfit for open repair, LEVAR may provide satisfactory 12 month overall survival and target vessel patency rates, though reported IOAE, mortality, and re-interventions rates were high thus requiring close and extensive follow up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Tomografia Computadorizada de Feixe Cônico , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Fluoroscopia , Mortalidade Hospitalar , Humanos , Complicações Intraoperatórias/etiologia , Terapia a Laser , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Complicações Pós-Operatórias/etiologia , Reoperação , Estudos Retrospectivos , Stents/efeitos adversos , Cirurgia Assistida por Computador , Taxa de Sobrevida , Grau de Desobstrução Vascular
12.
Ann Vasc Surg ; 71: 533.e7-533.e12, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32927040

RESUMO

BACKGROUND: We report a case of juxtarenal abdominal aortic aneurysm-anatomically unsuitable for conventional endovascular repair because of narrow distal aorta-successfully treated by endovascular repair facilitated by in situ laser fenestration. METHODS AND RESULTS: An aortic stent graft was inserted to exclude a juxtarenal aneurysm: under image fusion guidance, antegrade in situ laser fenestration allowed to perfuse superior mesenteric artery and both renal arteries. After complementary insertion of an extended aortouni-iliac stent graft, retrograde in situ laser fenestration was performed to perfuse the contralateral left iliac artery, in order to overcome a narrow distal aorta. Postoperative course was uneventful. Six month's CT showed an excluded aneurysm, patency of the inserted stents and the absence of endoleak. CONCLUSIONS: In situ laser fenestration seems to be an effective solution for endovascular therapy of complex juxtarenal aneurysms. In this case of narrow distal aorta it was a suitable alternative to overcome endovascular aneurysm repair anatomical restrictions and to prevent other additional open surgical interventions.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Fluxo Sanguíneo Regional , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Eur J Vasc Endovasc Surg ; 61(2): 201-209, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33342658

RESUMO

OBJECTIVE: The benefit of aneurysm sac coil embolisation (ASCE) during endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) remains unclear. This prospective randomised two centre study (SCOPE 1: Sac COil embolisation for Prevention of Endoleak) compared the outcomes of standard EVAR in patients with AAA at high risk of type II endoleak (EL with EVAR with ASCE during the period 2014-2019. METHODS: Patients at high risk of type II EL were randomised to standard EVAR (group A) or EVAR with coil ASCE (group B). The primary endpoint was the rate of all types of EL during follow up. Secondary endpoints included freedom from type II EL related re-interventions, and aneurysm sac diameter and volume variation at two year follow up. Adverse events included type II EL and re-interventions. CTA and Duplex ultrasound scans were scheduled at 30 days, six months, one year, and two years after surgery. RESULTS: Ninety-four patients were enrolled, 47 in each group. There were no intra-operative complications. At M1, 16/47 early type II EL occurred (34%) in group A vs. 2/47 (4.3%) in group B (p < .001). At M6, 15/36 type II EL (41.7%) occurred in group A vs. 2/39 (4.26%) in group B (p < .001). At M12, 15/37 type II El (40.5%) occurred in group A vs. 5/35 (14.3%) in group B (p = .018). At 24 months, 8/32 type 2 El (25%) occurred in group A vs. 3/29 (6.5%) in group B (p = .19). Kaplan-Meier curves of survival free from EL and re-interventions were significantly in favour of group B (p < .001). Aneurysm sac volume decreased significantly in group B compared with group A at M6 (p = .081), at M12 (p = .004), and M24 (p = .001). CONCLUSION: For selected patients at risk of EL, ASCE seems effective in preventing EL at one, six, and at 12 months. However, the difference was not statistically significant at 24 months. ASCE decreases the re-intervention rate two years after EVAR. A significantly faster aneurysm volume shrinkage was observed at one and two years following surgery. (SCOPE 1 trial: NCT01878240).


Assuntos
Aneurisma da Aorta Abdominal/terapia , Implante de Prótese Vascular/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Reoperação/estatística & dados numéricos , Resultado do Tratamento
15.
World J Emerg Surg ; 15(1): 40, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32600341

RESUMO

BACKGROUND: Ischemic colitis (IC) is a severe emergency in gastrointestinal surgery. The aim of the present study was to identify the predictors of postoperative mortality after emergent open colectomy for IC treatment. Additionally, we compared postoperative outcomes of patients undergoing emergent colectomy due to aortic surgery-related IC (AS-IC group) vs. other IC etiologies (Other-IC group). METHODS: We analyzed records of consecutive patients who underwent emergency open colectomy for IC between 2008 and 2019. Logistic regression analysis was performed to identify clinical and operative parameters associated with postoperative mortality. The AS-IC and Other-IC groups were compared for mortality, morbidity, ICU stay, hospital stay, and survival. RESULTS: During the study period, 94 patients (mean age, 67.4 ± 13.7 years) underwent emergent open colectomy for IC. In the majority of cases, IC involved the entire colon (53.2%) and vasopressor agents were required preoperatively (63.8%) and/or intraoperatively (78.8%). Thirty-four patients underwent surgery due to AS-IC, whereas 60 due to Other-IC causes. In the AS-IC group, 9 patients had undergone endovascular aortic repair and 25 open aortic surgery; 61.8% of patients needed aortic surgery for ruptured abdominal aortic aneurism (AAA). Overall, 66 patients (70.2%) died within 90 days from surgery. The AS-IC and Other-IC groups showed similar operative outcomes and postoperative complication rates. However, the duration of the ICU stay (19 days vs. 11 days; p = 0.003) and of the total hospital stay (22 days vs. 16 days; p = 0.016) was significantly longer for the AS-IC group than for the Other-IC group. The rate of intestinal continuity restoration at 1 year after surgery was higher for the Other-IC group than for the AS-IC group (58.8% vs. 22.2%; p = 0.05). In the multivariate model, preoperative increased lactate levels, a delay between signs/symptoms' onset and surgery > 12 h, and the occurrence of postoperative acute kidney injury were statistically associated with postoperative mortality. Neither IC etiology (aortic surgery vs. other etiology) nor ruptured AAA was associated with postoperative mortality. CONCLUSION: Emergency open colectomy for IC is associated with high postoperative mortality, which appears to be unrelated to the IC etiology. Preoperative lactate levels, > 12-h delay to surgery, and postoperative acute kidney injury are independent predictors of postoperative mortality.


Assuntos
Injúria Renal Aguda/mortalidade , Colectomia/mortalidade , Colite Isquêmica/mortalidade , Colite Isquêmica/cirurgia , Complicações Pós-Operatórias/mortalidade , Idoso , Biomarcadores/sangue , Emergências , Feminino , Humanos , Masculino , Fatores de Risco , Tempo para o Tratamento
16.
J Vasc Surg ; 71(6): 1834-1842.e1, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31708298

RESUMO

OBJECTIVE: Physician-modified fenestrated stent grafts (PMSGs) are a useful option for urgent or semiurgent treatment of complex abdominal aortic aneurysms (CAAAs). The aim of this study was to describe in-hospital outcomes of custom-made fenestrated stent grafts (CMSGs) and PMSGs for the treatment of CAAAs and thoracoabdominal aortic aneurysms (TAAAs). METHODS: In this single-center, retrospective study, all consecutives patients with CAAAs or TAAAs undergoing endovascular repair using Zenith CMSGs (Cook Medical, Bloomington, Ind) or PMSGs between January 2012 and November 2017 were included. End points were intraoperative adverse events, in-hospital mortality, postoperative complications, reinterventions, target vessel patency, and endoleaks. RESULTS: Ninety-seven patients were included (CMSGs, n = 69; PMSGs, n = 28). The PMSG group included more patients assigned to American Society of Anesthesiologists class 4 (n = 14 [50%] vs n = 16 [23%]; P = .006) and more TAAAs (n = 17 [61%] vs n = 10 [15%]; P < .0001). Intraoperative adverse events were recorded in eight (11%) patients in the CMSG group vs six (21%) patients in the PMSG group. No intraoperative death or open conversion occurred. In-hospital mortality rates were of 4% (n = 3) in the CMSG group and 14% in the PMSG group (n = 4). Chronic renal failure was an independent preoperative risk factor of postoperative death or complications (odds ratio, 4.88; 95% confidence interval, 1.65-14.43; P = .004). Rates of postoperative complications were 22% (n = 15) and 25% (n = 7) in the CMSG and PMSG groups. Spinal cord ischemia rates were 4% (n = 3) and 7% (n = 2) in the CMSG and PMSG groups. Reintervention rates were 16% (n = 11) in the CMSG group and 32% (n = 9) in the PMSG group. At discharge, target vessel patency rate in CMSGs was 98% (n = 207/210). All target vessels (n = 98) were patent in the PMSG group. Endoleaks at discharge were observed in 24% of the CMSG group (n = 16) vs 8% of the PMSG group (n = 2). CONCLUSIONS: Our study showed clinically relevant differences of several important in-hospital outcomes in the CMSG and PMSG groups. Larger cohorts and longer follow-up are needed to allow direct comparison. PMSGs may offer acceptable in-hospital results in patients requiring urgent interventions when CMSGs are not available or possible.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Ann Vasc Surg ; 66: 601-608, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31866550

RESUMO

BACKGROUND: To describe a hybrid approach for complex iliofemoral lesions and report short-term and mid-term results. METHODS: In this single-center retrospective study, all consecutive patients (n = 32, 36 limbs) who underwent hybrid repair of complex iliofemoral lesions between 2012 and 2017 using a conformable self-expandable covered stent for external iliac artery lesions and open repair of the common femoral artery were included. Lesions were responsible for claudication in 13 (36%) limbs, rest pain in 13 (36%) limbs and tissue loss in 10 (28%) limbs. Over a wire crossing the iliac lesion, the covered stent was deployed, externalized through the femoral arteriotomy, and cut at the iliofemoral junction in such a way that no untreated transition zone remained between the stent and the open reconstruction of the femoral artery. RESULTS: Two elderly patients with critical limb ischemia died during the postoperative course, giving in-hospital mortality of 6.2%. Four (12.5%) presented with moderate to severe complications, including one transtibial amputation in a patient who presented with tissue loss at admission. The median follow-up period was 24.1 months (range: 0.8-64 months). One-year and two-year Kaplan-Meier estimates of overall survival were 91% (95% CI: 97-74) and 76% (95% CI: 89-53). One-year and two-year estimates of freedom from major amputation were 96% (95% CI: 99-76) and 91% (95% CI: 97-66). Estimates of primary patency, assisted primary patency, and secondary patency were: 93.7 (95% CI: 77.1-98.4) at 1 year, and 93.7 (95% CI: 77.1-98.4) at 2 years; 96.7% (95% CI: 78.6-99.6) at 1 year, and 96.7% (95% CI: 78.6-99.6) at 2 years; 96.7% (95% CI: 78.6-99.6) at 1 year and 96.7% (95% CI: 78.6-99.6) at 2 years, respectively. CONCLUSIONS: Our hybrid approach for iliofemoral lesions provided acceptable mortality and good mid-term patency rates. Further studies with long-term followup are needed to evaluate the safety and durability of this technique.


Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Artéria Ilíaca , Claudicação Intermitente/terapia , Doença Arterial Periférica/terapia , Stents , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Terapia Combinada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Mortalidade Hospitalar , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/mortalidade , Claudicação Intermitente/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Eur J Vasc Endovasc Surg ; 59(2): 237-246, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31865026

RESUMO

OBJECTIVE: The aim was to validate a computational patient specific model of Zenith® fenestrated device deployment in abdominal aortic aneurysms to predict fenestration positions. METHODS: This was a retrospective analysis of the accuracy of numerical simulation for fenestrated stent graft sizing. Finite element computational simulation was performed in 51 consecutive patients that underwent successful endovascular repair with Zenith® fenestrated stent grafts in two vascular surgery units with a high volume of aortic procedures. Longitudinal and rotational clock positions of fenestrations were measured on the simulated models. These measurements were compared with those obtained by (i) an independent observer on the post-operative computed tomography (CT) scan and (ii) by the stent graft manufacturer planning team on the pre-operative CT scan. (iii) Pre- and post-operative positions were also compared. Longitudinal distance and clock face discrepancies >3 mm and 15°, respectively, were considered significant. Reproducibility was assessed using Bland-Altman and linear regression analysis. RESULTS: A total of 195 target arteries were analysed. Both Bland-Altman and linear regression showed good reproducibility between the three measurement techniques performed. The median absolute difference between the simulation and post-operative CT scan was 1.0 ± 1.1 mm for longitudinal distance measurements and 6.9 ± 6.1° for clock positions. The median absolute difference between the planning centre and post-operative CT scan was 0.8 ± 0.8 mm for longitudinal distance measurements and 5.1 ± 5.0° for clock positions. Finally, the median absolute difference between the simulation and the planning centre was 0.96 ± 0.97 mm for longitudinal distance measurements and 4.8 ± 3.6° for clock positions. CONCLUSION: The numerical model of deployed fenestrated stent grafts is accurate for planning position of fenestrations. It has been validated in 51 patients, for whom fenestration locations were similar to the sizing performed by physicians and the planning centre.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Modelagem Computacional Específica para o Paciente , Stents , Aorta/diagnóstico por imagem , Aortografia/métodos , Procedimentos Endovasculares/métodos , Humanos , Período Pós-Operatório , Período Pré-Operatório , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Ann Vasc Surg ; 61: 471.e3-471.e7, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31394215

RESUMO

The present case describes acute and early infection of a superficial femoral artery drug-eluting stent (DES) in a 65-year-old patient 2 days after its implantation in outpatient clinic, with intense clinical presentation. The initial indication was Rutherford 3 peripheral artery disease. Radical treatment by means of stent explantation and femoro-femoral bypass using autogenous vein was performed. Both stent and blood cultures were positive for methicillin-sensitive Staphylococcus aureus. Informative imaging and intraoperative view are provided. Local evolution was satisfactory but endocarditis occurred secondarily. The pathophysiology of this first reported DES infection and the management of the infected vessel are discussed, in light of data derived from coronary literature and open vascular surgery.


Assuntos
Stents Farmacológicos/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Artéria Femoral/microbiologia , Doença Arterial Periférica/terapia , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/microbiologia , Idoso , Antibacterianos/uso terapêutico , Remoção de Dispositivo , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Artéria Femoral/cirurgia , Humanos , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Veia Safena/transplante , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/cirurgia , Fatores de Tempo , Resultado do Tratamento
20.
Cardiovasc Intervent Radiol ; 42(12): 1800-1805, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31435757

RESUMO

PURPOSE: This technical note describes a total percutaneous technique to perform ultrasound and fluoroscopy-assisted femoropopliteal bypass in long superficial femoral artery (SFA) lesions, using standard equipment, through a juxta-anatomical superficial femoral vein (SFV) tunnel. MATERIALS AND METHODS: Three percutaneous accesses were obtained under ultrasound guidance. The first was retrograde, with crossover maneuver, at the contralateral groin. The second was a proximal SFV-to-SFA stump puncture. The third was a distal popliteal artery-to-popliteal vein puncture. Through the described snaring and capture maneuvers, one single 0.018″ guide wire entered the femoral vein through the SFA stump and re-entered the popliteal artery distally. The fistulous tracts were then dilated and covered stents deployed and post-dilated. RESULTS: Three patients aged 68 ± 3 years and presenting Rutherford 4 chronic limb ischemia were treated with this technique. The mean SFA lesion length was 22.6 ± 3 cm. The mean procedure duration was 88 ± 18 min. No intraoperative complication occurred. The postoperative course was uneventful. In particular, no deep vein thrombosis occurred. Rutherford stage decreased from 4 to 1 in all patients, with a mean follow-up duration of 6.6 ± 2 months. CONCLUSION: The main advantage of the technique is avoiding calcification issues by abandoning the trans-arterial recanalization approach for long calcified lesions. The second interest is its feasibility by simple endovascular means without any particular or dedicated device. However, longer follow-up is needed to assess safety and durability.


Assuntos
Artéria Femoral/fisiopatologia , Artéria Femoral/cirurgia , Doenças Vasculares Periféricas/cirurgia , Artéria Poplítea/diagnóstico por imagem , Procedimentos Cirúrgicos Vasculares/métodos , Idoso , Feminino , Artéria Femoral/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Masculino , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/fisiopatologia , Radiografia Intervencionista , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA